Open Access Open Access  Restricted Access Subscription or Fee Access

Study of 9MW Wind Farm with and without STATCOM Using MATLAB/SIMULINK

V. Kumar, Kalagotla Chenchireddy, Khammampati R. Sreejyothi

Abstract


Voltage Stability could be a key challenge for the stable operation of grid connected wind farm through-out the faults and grid interruptions. When the wind farm is directly connected to grid, the voltage stability is that the main issue for Squirrel Cage Induction Generator (SCIG) because of intermittent nature of wind velocity. Voltage stability drawback is sorted out with the help of Flexible AC Transmission System (FACTS) devices like static synchronous compensator (STATCOM). A STATCOM is used to counter problems like transient stability support in network including Squirrel Cage wind generator. The wind power system model is implemented using SIMULINK. The STATCOM results are better than Static Var Compensator (SVC) for the stable operation of SCIG. STATCOM improves the stability problem and so help the wind generator system to remain in service throughout grid faults.

Keywords


Wind Farm, STATCOM, Reactive Power, Squirrel Cage Induction Generator.

Full Text:

PDF

References


Rajiv Singh, “Transient Stability Improvement of a FSIG Based Grid Connected Wind Farm with the help of a SVC and a STATCOM: A Comparison”, International Journal of Computer and Electrical Engineering, Vol.4, No.1, February 2012.

CH.Appala Narayana, “Application of STATCOM for Transient Stability Improvement and Performance Enhancement for a Wind Turbine Based Induction Generator” , International Journal of Soft Computing and Engineering (IJSCE) ISSN: 2231-2307, Volume-2, Issue- 6, January 2013.

Sharmila,Pardeep Nain, “Analysis of IG Based Wind Farm with STATCOM and SVC in MATLAB/SIMULINK”,IJESRT,4.(7):July,2015,pp.1163 -1169.

Mahmoud Ebadian, Mohsen Noruzin Azghandi, “Harmonic Analysis of Voltage in Different Wind Speeds for Wind Farms”, International Journal of Advanced Research in Computer Science and Software Engineering, Vol.4, Issue-11, November 2014, pp.30-35.

K.B. Mohd. Umar Ansari, “Use of STATCOM for Improving Dynamic Performance of Wind Farms Connected in Power Grid”, International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering,Vol 3, Issue-9 September 2014,pp.11738-11748.

Naimul Hasan, “Dynamic Performance Analysis of DFIG Based Wind Farm with Statcom and SVC”, International Journal of Emerging Technology and Advanced Engineering, Vol. 2, Issue-7, July 2012, pp.461-469.

Pradeep Kumar, “Dynamic Performance of STATCOM on the Induction Generator based Wind Farm”, International Conference on Global Scenario in Environment and Energy ICGSEE-2013[14th – 16th March 2013], Vol.5, pp.2462-2470, July-Sept 2013.

Bouhadouza Boubekeur, “Application of STATCOM to Increase Transient Stability of Wind Farm”, American Journal of Electrical Power and Energy Systems. Vol. 2, No. 2, 2013.

Deshveer, Sudhir Malik, “Simulation and Modeling of STATCOM and WINDFARM in transmission line using MATLAB and analysis of bus voltage”, International Journal of Enhanced Research in Science, Technology &Engineering, ISSN: 2319-7463, Vol. 5, Issue 6, June- 2016.

Sravanthi, P., Rani, K. R., Amarnath, J., & Kamakshaiah,S. (2014, September). Critical clearing time and transient stability analysis of SCIG based wind farm with STATCOM. In Smart Electric Grid (ISEG), 2014 International Conference on (pp. 1-8). IEEE.


Refbacks

  • There are currently no refbacks.