Design of Four Channel Uniform Filter Bank and Oversampled Three Channels FIR Filter Banks for 2-D Image

S.R. Chougule, Dr.R.S. Patil

Abstract


In this paper comparison of four channel uniform critical sampled filter bank with proposed oversampled three channels FIR filter banks [FB] is carried out for two dimensional ((2-D )medical image. Three channels are selected likewise which gives the result near perfect reconstruction filter bank. The inband aliasing is significantly reduced by selecting proper frequency spectrum and design of filters of filter banks. Results of oversampled FIR filter bank and 4-channel uniform filter bank for two dimensional MRI image with energy and histogram of images are compared. By applying wavelet transform energy is preserved at output of oversampled filter banks. Comparison of energy restored at output image of each filter bank with input image energy is carried out. Proposed 3-channel filter bank output gives better results.

Keywords


FIR Filter Bank, Oversampled Filter Bank

Full Text:

PDF

References


“A filterbank design for oversampled filter banks without aliasing in the subbands”

By Moritz Harteneck, Robert W. Stewart and J.M. Paez-Borrallo. Signal Processing division ,dept. of Electricalk & Electronics Engineering Uinversity of Strathclyde Glasgow,GI1XW,UK. http://citeseer.ist.psu.edu/31230.html

“An oversampled filter bank with different analysis and synthesis filters for the use with adaptive filters” By Moritz Harteneck,Stephan Weiss, and Robert W. Stewart Signal Processing division ,dept. of Electricalk & Electronics Engineering Uinversity of Strathclyde Glasgow, GI 1XW,UK. http://citeseer.ist.psu.edu/

“Design of near perfect reconstruction oversampled filter banks for subband adaptive filters”. By Moritz Harteneck,Stephan Weiss, and Robert W. Stewart Signal Processing division ,dept. of Electricalk & Electronics Engineering Uinversity of Strathclyde Glasgow, GI 1XW,UK. http://citeseer.ist.psu.edu/

“A New Flexible Bi-Orthogonal Filter Design for Multiresolution filterbanks with application to image compression” By Nikolay Polyak ans William A. Pearlman,Fello, IEEE Tran. Signal processing vol.48 no.8 Aug.2000.

”An oversampled subband adaptive filter without cross adaptive filters” By Moritz Harteneck,Stephan Weiss, and Robert W. Stewart Signal Processing division ,dept. of Electricalk & Electronics Engineering Uinversity of Strathclyde Glasgow, GI 1XW,UK. http://citeseer.ist.psu.edu/

“A filter bank design for oversampled filter banks without aliasing in the subbands”2nd UK symposium on applications of time-frequency and time scale methods(TFTS) Warwick, England,27-29 August 1997,1997.

“Thin-Section MRI with a Phased-Array Coil for Preoperative Evaluation of Pelvic Anatomy and Tumor Extent in Patients with Rectal Cancer” Colorectal Surgery Division, National Cancer Center Hospital, 5-1-1, Tsukiji, Chuo-ku, Tokyo 104-0045, Japan.and. Diagnostic Radiology Division, National Cancer Center Hospital, Tokyo104-0045,Japan http://www.ajronline.org/cgi/content/full.


Refbacks