Abstract


 

Our country India is facing some drastic changes in the climatic conditions due to the heating effect caused by various greenhouse gases. The most harmful gas among them is the hydrocarbon family and is increasing at an uncontrolled rate. Hence an effective sensing and communicating system is required. This paper aims in finding out the quantity of the major polluting gas methane. The gravimetric sensor works by absorbing the chemical in a hydrocarbon sponge, which alters the overall mass of the sensing element i.e a cantilever, thereby its resonant frequency. Here a micro-cantilever beam is fabricated using selective Silicon Carbide coatings on the surface to selectively absorb the hydrocarbons. As the gases are absorbed the mass increases and hence there is a change in resonant frequency. This change in frequency gives the measure of the quantity of gas present in that environment. The major expected advantage of this technique would be the repeatability of the sensor that is used.


Keywords


MEMS, Cantilever, Resonant Frequency, Signal Conditioning Circuit.

Full Text:

PDF

References


I. Voiculescu, M. Zaghloul, A. McGill, “ Cantilever Gas Sensor”, The Proceedings of the IEEE International Symposium on Circuits and Systems, Bangkok, Thailand, May 25-28, 2003.

M. Roukes, Solid-state Sensor and Actuator Workshop, Hilton Head Island, 2000, pp. 367-370.

Alexis Madrigal, New CO2 Capturing Material Could Make Plants Cleaner, ScienceDaily, Feb. 14, 2008

E. S. Snow, F. K. Perkins, E. J. Houser, S. C. Badescu, and T. L. Reinecke, “Chemical detection with a single-walled carbon nanotube capacitor,” Science, vol. 307, no. 5717, pp. 1942–1945, Mar. 2005.

S. J. Ippolito, A. Ponzoni, K. Kalantar-Zadeh, W. Wlodarski, E. Comini, G. Faglia, and G. Sberveglieri, “Layered WO3/ZnO/36. LiTaO3 SAW gas sensor sensitive towards ethanol vapour and humidity,” Sens. Actuators B, Chem., vol. 117, no. 2, pp. 442–450, Oct. 2006.

D. Then, A. Vidic, and C. Ziegler, “A highly sensitive self-oscillating cantilever array for the quantitative and qualitative analysis of organic vapor mixtures,” Sens. Actuators B, Chem., vol. 117, no. 1, pp. 1–9, Sep. 2006.

K. Zinoviev, C. Dominguez, J. A. Plaza, V. J. C. Busto, and L. M. Lechuga, “A novel optical waveguide microcantilever sensor for the detection of nanomechanical forces,” J. Lightw. Technol., vol. 24, no. 5, pp. 2132–2138, May 2006.