Open Access Open Access  Restricted Access Subscription or Fee Access

Analysis of Ozone Generation with Effect of Voltage, Frequency, (Temperature) and Flow Rate using Corona Discharge

V. Lakshminarayanan, P.A. Balakrishnan, T. Karthick Kumar

Abstract


This paper rationale a high voltage power supply which varies of (O-5) kV with the variable frequency of 50 Hz-5 kHz. The power supply is used in the dielectric barrier discharge tube for the ionization process to yield concentration of ozone.This setup points the development of small and high efficient ozone generators using corona discharge method. Ozone generation was carried out by varying parameters including voltage, frequency, flow rate and temperature to yield high concentration of ozone. The feeding gas composition greatly affected the ozone generation rate, which was increased in order of ambient air to dry air. With increase in temperature, ozone concentration is increased while ozone generation rate is enhanced. In the experiments, a maximum ozone concentration of approximately 83 ppm is obtained, the peak value of applied voltage of about 5kV and gap of electrode is 4.3mm respectively. Dry air is used as feeding gas with residence time of 10.58 sec.

Keywords


Ferrite Core Transformer, Temperature Sensor (LM35), Ozone Analyzer & Air Compressor.

Full Text:

PDF

References


M. Takayamaa,*, K. Ebiharaa, H. Stryczewskaa,”Ozone generation by dielectric barrier discharge for soil sterilization” in ELSEVIER, vol.506–507 Pg.no.396 – 399, 18 October 2005.

Shunichi Kaneda*, Nobuya Hayashi, Satoshi Ihara &Saburoh Satoh,, “Application of dielectric material to double-discharge-type ozonizer,” in ELSEVIER, vol:73, Pg.no:567-571,2004.

How Ming Lee, Moo Been Chang and Ta Chin Wei,” Kinetic Modeling of Ozone Generation via Dielectric Barrier Discharges” in Ozone: Science and Engineering, vol. 26: no.551–562 8 December 2003.

Hee-Sung AHN, Nobuya HAYASHI, Saburoh SATOH “Ozone Generation Characteristics of Superimposed Discharge with Surface and DC Discharge” in Reports of the Faculty of Science and Engineering, Vol. 30, No.1, 2001.

SiseerotKetkaew, “The Case Study of 5kHZ-25kHZ High frequency Adjustment in Converter Circuit to Generate Ozone Gas,” Univ. ofRamkhamhaeng, Tech. Rep. 42-47, jul.2007.

C. Boonseng and V. Kinnares,”Harmonic Analysis of Corona Discharge 0zone.Generator Using Brush Electrode Configuration “in IEEE 2010, p.no:403-408.

Wei Linsheng, Hu Zhaoji, Zhang Yafang and Wu Qinfen “Experimental Study on Ozone Generation and Ozone Oxidation to Removal Multi-Pollutant of Flue Gas” in IEEE2010, Doi:10.1109/ICBBE.2010.5515999 , p.no:1-4

Yukihiro Kamase, Masami Shimizu, Akira Mizuno, and Tadashi Nagahama” Pulsed High Voltage Source for Ozone Generator” in IEEE 1991, vo:1,p.no:693-697.

Seunghunbeak, yu du, and gangyaowang, “Design Considerations of High Voltage and High Frequency Transformer for Solid State Transformer Application” in IEEE 2010 p.no 421-498.

Z Bo and J H Chen,” Dimensional analysis of detrimental ozone generation by positive wire-to-plate corona discharge in air” in IOP 2010, p.no:1-8, 29 January 2010.


Refbacks

  • There are currently no refbacks.