Application of Diagnostic Techniques to Power Transformer – A Case Study

Yogesh Y. Pundlik

Abstract


Acoustic Emission (AE) is a nondestructive testing method that has been successfully used in a variety of applications dating back to the early 1970s. It covers the detection of structural-borne sound (in the ultrasonic range) that has been generated by some source of distress. An application has been developed for in-service testing of power transformers to detect, locate and assess both thermal and electrical faults from the sounds originating inside a transformer. DGA is performed on oil-filled transformers all over the world, and the main standards providing guidance for use, analysis, and applications are contained in ANSI/IEEE C57.104 and IEC 60599, commonly known as the "gas guides". The use of DGA as a powerful diagnostic tool is a critical and important aspect of determining the condition and health of a transformer, but it is still not entirely effective as most people tend to use it today.

Keywords


Acoustic Emission (AE), Power Transformers, Faults, Partial Discharge (PD), Dissolved Gas Analysis (DGA).

Full Text:

PDF

References


Dind, J.E., Daoust, R., Regis, J. and Morgan, J., (1971). Analysis of Gases Dissolved in Transformer Oils, Progress Report. Minutes of the Thirty-Eighth Annual International Conference of Doble Clients. Sec. 6-1101.

Dind, J.E., Daoust, R., Regis, J. and Morgan, J., (1971). Analysis of Gases Dissolved in Transformer Oils, Progress Report. Minutes of the Thirty-Eighth Annual International Conference of Doble Clients. Sec. 6-1101.

Jalbert, J., Gilbert, R. and Brillante, S., (1995). Dissolved Gas Analysis of Transformer Insulating Oils by Headspace/Capillary Gas Chromatography. Hewlett Packard Application Note. pp. 228-310.

Griffin, P.J., (1998). Criteria for the Interpretation of Data for Dissolved Gases in Oil from Transformers (A Review). ASTM Special Technical Publication 998.

Lewand, L.R. and Griffin, P.J., (2000). The Effective Use of Laboratory Analysis of Insulating Oil as a Maintenance Tool. Proceedings of the Sixty-Seventh Annual

International Conference of Doble Clients. Sec. 5-8.

Griffin, P. J. and Lewand, L.R., (1995). A Practical Guide for Evaluating the Condition of Cellulosic Insulation in Transformers. Proceedings of the Sixty-Second Annual International Conference of Doble Clients. Sec. 5-6.

Sukhbir Singh and M.N. Bandyopadhyay, Dual Traingle:A Noble Technique for DGA in Power Transformers, International Journal of Electrical and Power Engineering , 193-197, 2010, ISSN:: 1990-7958


Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution 3.0 License.